Finalised configurations
35 configurations across 36 documented models. Find yours by the outlet you have, or by what you need to pump.
Two ways in. If you already know the discharge size you need, use the list below. If you know the duty and not the size, skip to the application list further down. Flow and head are the two ends of each model's range.
By discharge size
Every configuration in the finalised price list, grouped by outlet. Each row is one buildable pump.
2" / 2.5" / 3"
| Discharge | Motor rating | Max flow (m³/h) | Max head (m) | Weight (kg) | Class |
|---|---|---|---|---|---|
| 2" / 2.5" / 3" | 7.5KW 2-stage | 70 | 70 | 26 | Rod-coupled high head |
| 2" / 2.5" / 3" | 9.2KW 3-stage | 70 | 105 | 31 | Rod-coupled high head |
| 2" / 2.5" / 3" | 11KW 4-stage | 70 | 135 | 37 | Rod-coupled high head |
| 2" / 2.5" / 3" | 15KW 5-stage | 70 | 165 | 42 | Rod-coupled high head |
2" / 3" / 4"
| Discharge | Motor rating | Max flow (m³/h) | Max head (m) | Weight (kg) | Class |
|---|---|---|---|---|---|
| 2" / 3" / 4" | 5.5KW | 80 | 35 | 20 | High head, 5.5-11 kW |
| 2" / 3" / 4" | 7.5KW | 110 | 35 | 23 | High head, 5.5-11 kW |
| 2" / 3" / 4" | 7.5KW 2-stage | 90 | 60 | 33 | High head, 5.5-11 kW |
| 2" / 3" / 4" | 11KW 3-stage | 90 | 100 | 41 | High head, 5.5-11 kW |
3"
| Discharge | Motor rating | Max flow (m³/h) | Max head (m) | Weight (kg) | Class |
|---|---|---|---|---|---|
| 3" | 5.5KW | 40 | 35 | 38 | sewage / cutting pumps |
| 3" | 5.5KW | 80 | 18 | 39 | sewage / cutting pumps |
| 3" | 7.5KW | 100 | 22 | 44 | sewage / cutting pumps |
| 3" | 7.5KW | 150 | 15 | 45 | sewage / cutting pumps |
| 3" | 11KW | 150 | 25 | 75 | sewage / cutting pumps |
| 3" | 11KW | 260 | 12 | 76 | sewage / cutting pumps |
| 3" | 15KW | 150 | 35 | 86 | sewage / cutting pumps |
| 3" | 15KW | 255 | 15 | 88 | sewage / cutting pumps |
4"
| Discharge | Motor rating | Max flow (m³/h) | Max head (m) | Weight (kg) | Class |
|---|---|---|---|---|---|
| 4" | 5.5KW | 120 | 25 | 19 | Stretched-body permanent magnet |
| 4" | 7.5KW | 180 | 16 | 21 | Stretched-body permanent magnet |
| 4" | 7.5KW | 240 | 10 | 25 | Stretched-body permanent magnet |
| 4" | 11KW | 270 | 15 | 28 | Stretched-body permanent magnet |
6"
| Discharge | Motor rating | Max flow (m³/h) | Max head (m) | Weight (kg) | Class |
|---|---|---|---|---|---|
| 6" | 5.5KW | 300 | 10 | 20 | 6 inch outlet |
| 6" | 7.5KW premium | 180 | 25 | 25 | 6 inch outlet |
| 6" | 7.5KW | 350 | 10 | 23 | 6 inch outlet |
| 6" | 11KW | 400 | 12 | 25 | 6 inch outlet |
| 6" | 11KW premium | 200 | 30 | 25 | 6 inch outlet |
| 6" | 18.5KW | 280 | 30 | 30 | High head, 18.5-22 kW |
| 6" | 22KW | 280 | 35 | 32 | High head, 18.5-22 kW |
| 6" | 22KW reinforced | 280 | 38 | 47 | High head, 18.5-22 kW |
8"
| Discharge | Motor rating | Max flow (m³/h) | Max head (m) | Weight (kg) | Class |
|---|---|---|---|---|---|
| 8" | 7.5KW | 350 | 10 | 23 | 8 inch outlet |
| 8" | 11KW | 400 | 12 | 25 | 8 inch outlet |
| 8" | 15KW reinforced | 480 | 12 | 28 | 8 inch outlet |
| 8" | 18.5KW | 500 | 12 | 30 | Flood emergency, high flow |
| 8" | 22KW | 500 | 15 | 32 | Flood emergency, high flow |
| 8" | 22KW reinforced | 500 | 15 | 47 | Flood emergency, high flow |
| 8" | 45KW | 1000 | 10 | 75 | Flood emergency, high flow |
Figures shown here are transcribed one by one from the factory price list and manual. The binding reference for any order is the factory document and the nameplate on the unit itself.
By what you are pumping
Seven duty bands we build for. Each names the series that covers it, with the flow and head ceiling of that combination.
Flood response and emergency stock
Speed of deployment matters more than efficiency. No civil works, one person to move it.
Municipal surface and road drainage
Usually a fixed install, so automatic level control matters more than portability.
Foundation pit and site dewatering
Tight site, silty water, units repositioned as the work proceeds.
Mining and metallurgy drainage
Sand, silt and metal fines. Solids handling decides the series.
Sewage, sludge and pond desilting
Flow figures stay modest on purpose — the pump has to move solids, not just water.
Irrigation and long-distance transfer
Long run hours at part load, so energy cost over the season decides it.
High-lift and hillside supply
Above 60 m the stack height is the whole game — single stage runs out of head.
Tell us the outlet you have
If you have a fixed pipe size or a pump to replace, give us the discharge and the duty. We will tell you which of these configurations fits, or whether a different outlet is the better answer.